1 / 5
| Model | EMC PowerEdge R760 |
| Customization Intention | Customers Can Freely Choose Specific Configurations |
| Processor | Up to two 4th Generation Intel Xeon Scalable or Intel Xeon Max processors with up to 56 cores per processor and with optional Intel® QuickAssist Technology. Up to two 5th Generation Intel Xeon Scalable processors with up to 64 cores per processor. |
| Memory | 32 DDR5 DIMM slots, supports RDIMM 8 TB max, Speeds up to 4800 MT/s on the 4th Generation Intel Xeon Scalable or Intel Xeon Max processors Speeds up to 5600 MT/s on the 5th Generation Intel Xeon Scalable processors Supports registered ECC DDR5 DIMMs only |
| Storage controllers | Internal Controllers: PERC H965i, PERC H755, PERC H755N, PERC H355 External Controller: PERC H965e Internal Boot: Boot Optimized Storage Subsystem (BOSS-N1): HWRAID 2 x M.2 NVMe SSDs or USB SAS HBA (non-RAID): HBA355e, HBA355i, HBA465i Software RAID: S160 |
| Drive Bay | Front bays: • Up to 12 x 3.5-inch SAS/SATA (HDD/SSD) max 240 TB • Up to 8 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 122.88 TB • Up to 16 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 245.76 TB • Up to 16 x EDSFF E3.S Gen5 NVMe (SSD) max 122.88 TB • Up to 24 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 368.64 TB Rear bays: • Up to 2 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 30.72 TB • Up to 4 x 2.5-inch SAS/SATA/NVMe (HDD/SSD) max 61.44 TB • Up to 4 x EDSFF E3.S Gen5 NVMe (SSD) max 30.72 TB |
| Power Supplies | • 3200 W Titanium 277 VAC or 336 HVDC, hot swap redundant • 2800 W Titanium 200—240 HLAC or 240 HVDC, hot swap redundant • 2400 W Platinum 100—240 VAC or 240 HVDC, hot swap redundant • 1800 W Titanium 200—240 HLAC or 240 HVDC, hot swap redundant • 1400 W Titanium 277 VAC or 336 HVDC, hot swap redundant • 1400 W Platinum 100—240 VAC or 240 HVDC, hot swap redundant • 1100 W Titanium 100—240 VAC or 240 HVDC, hot swap redundant • 1100 W -(48—60) VDC, hot swap redundant • 800 W Platinum 100—240 VAC or 240 HVDC,hot swap redundant • 700 W Titanium 200—240 HLAC or 240 HVDC, hot swap redundant |
| Cooling Options | • Air cooling • Optional Direct Liquid Cooling (DLC) Note: DLC is a rack solution and requires rack manifolds and a cooling distribution unit (CDU) to operate. |
| Fans | • Standard (STD) fans/High performance Silver (HPR Silver) fans/ High performance Gold (HPR Gold) fans • Up to 6 hot plug fans |
| Dimensions | • Height – 86.8 mm (3.41 inches) • Width – 482 mm (18.97 inches) • Depth – 772.13 mm (30.39 inches) with bezel 758.29 mm (29.85inches) without bezel |
| Form Factor | 2U rack server |
| Embedded Management | • iDRAC9 • iDRAC Direct • iDRAC RESTful API with Redfish • iDRAC Service Module • Quick Sync 2 wireless module |
| Bezel | Optional LCD bezel or security bezel |
| OpenManage Software | • CloudIQ for PowerEdge plug in • OpenManage Enterprise • OpenManage Enterprise Integration for VMware vCenter • OpenManage Integration for Microsoft System Center • OpenManage Integration with Windows Admin Center • OpenManage Power Manager plugin • OpenManage Service plugin • OpenManage Update Manager plugin |
| Mobility | OpenManage Mobile |
| OpenManage Integrations | • BMC Truesight • Microsoft System Center • OpenManage Integration with ServiceNow • Red Hat Ansible Modules • Terraform Providers • VMware vCenter and vRealize Operations Manager |
| Security | • Cryptographically signed firmware • Data at Rest Encryption (SEDs with local or external key mgmt) • Secure Boot • Secure Erase • Secured Component Verification (Hardware integrity check) • Silicon Root of Trust • System Lockdown (requires iDRAC9 Enterprise or Datacenter) • TPM 2.0 FIPS, CC-TCG certified, TPM 2.0 China NationZ |
| Embedded NIC | 2 x 1 GbE LOM card (optional) |
| Customized requirements | Support |